Laserscanner installation manual vesda 2 version 1. Vesda laser scanner manual printable 2019 online reading at pedromoreno. The detector chamber can detect presence of smoke at very low concentrations. Vesda vls314 laserscanner asd 12 relays programmer. This vesda product incorporates a laser device and is classified as a class 1. Vesda laser scanner vls detector the xtralis vesda vls is similar to the standard xtralis vesda vlp detector, but also includes a valve mechanism in the inlet manifold and software to control the airflow from the four sectors pipes. Use the following point types for the following vesda systems. Laserfocus vlf500 product guide vesda 36 filter replacement the vesda laserfocus smoke detector uses a disposable dual stage air filter cartridge. Introduction scope of this manual this manual is intended for installation technicians to be able to install, perform basic power and. The vesda laserplus is an aspirating smoke detection unit providing very early warning of fire conditions by drawing air samples through an air sampling pipe network. A very early smoke detection system similar to the vesda laserscanner system shall be installed throughout the areas nominated on the drawings. Vesda laser scanner manual printable 2019 in simple step and you can download it now.
Vesda vlp the vesda vlp detector is the central element of the vesda asd product range. This vesda product incorporates a laser device and is classified as a class 1 laser product that complies with fda regulations 21 cfr the laser is housed in a sealed detector chamber and contains no serviceable parts. The vesda vls by xtralis is similar to the flagship vesda vlp aspirating smoke detector but also includes a valve mechanism in the inlet manifold and software to control the airflow from the four sectors pipes. This manual introduces you to the xtralis vesda vls features, technical. The detection of smoke results in the system locating the sector in alert. These instructions must be followed to avoid damage to this product and associated. Vesda is a very early warning aspirating smoke detector. In addition to the features found in all xtralis laser products, vesda vlf provides a new range of features and builtin intelligence for quick installation, commissioning and servicing. Scenevision3d provides a complete solution for working with 3d laser data, including scan alignment, model building, panoramic images, measurement, analysis, and presentation. A separate nonscanning vesdanetcapable detector is used to draw air from. A zone is broken down into four sectors and air samples are taken from all sectors. The laser scanner uses pulse ranging technology prt.
The detector constantly monitors filter efficiency. The vesda e range of detectors sets a new benchmark in the life safety industry. Vesda sectors pipes the software configuration enables one 1 vesda zone to be divided into four 4 separate sectors. Conditions, user manual and product documents available from xtralis. Vesda vls204 laserscanner asd 7 relays display panel. The detector will be able to identify which pipe is carrying smoke. The fast scan sequence for each pipe is approximately 4 seconds. Fm, lpc, ssl, ul, ulc, vds the laserscanner is similar to the the laserscanner display standard laserplus detector, but also the laserscanner display has a bar graph includes a valve mechanism in the inlet to indicate the overall smoke level, alarm manifold and software to. With the arrival of the new vesda e ves detector, the vesda laserscanner vls has been discontinued immediately in all regions except europe. It is recommended that only persons who have an understanding of vesda laser products and aspirating smoke detection systems attempt at troubleshooting a vesda laser system. Fm, lpc, ssl, ul, ulc, vds the laserscanner is similar to the the laserscanner display standard laserplus detector, but also the laserscanner display has a bar graph includes a valve mechanism in the inlet to indicate the overall smoke level, alarm manifold and software to control the threshold. Vesda vls aspirating smoke detector vls with the arrival of the new vesdae ves detector, the vesda laserscanner vls has been discontinued immediately in all regions except europe. This laser emits invisible light and can be hazardous if viewed with the naked eye.
Once fast scan is completed and the fas identified, the vls continues to closely monitor all four. There can be a maximum of 30 vesda units per interface card. Laserfocus vlf500 product guide vesda filter replacement. Nikon metrologys optical measuring systems include autocollimators, digital height gages, measuring microscopes, optical comparators and software. The laser is housed in a sealed detector chamber and contains no serviceable parts. Square off and deburr the end of the sampling air pipes, ensuring the pipes are free from debris. Vesda xtralis vps100us120 24vdc power supply new never installed. Burkert side control 1067 manual vesda laser plus user manual for mac downloaded and installed quickly. Vesda addressing the vesda units address is obtained throug h the facp programmer when a vesda point is added to the job. Get the best deals on vesda when you shop the largest online selection at.
Vesda vls laser scanner data sheet linkedin slideshare. Manuals and user guides for vesda lasercompact vlc505. Individual pipe identification adaptive scan threshold wide sensitivity range laser based smoke detection vesdanet communication 4 alarm levels per sector high efficiency aspirator dual stage air filter easy to replace air filter 7 or 12 programmable relays option autolearn ref. During the fast scan operation the vesda vls samples air from each sector pipe separately by controlling the scanner valves in the inlet manifold. Opened in 2006, the hicc has a pillarfree internal hall measuring 6,480 square. The vls locates the origin of smoke by identifying the first sector pipe with the highest level of smoke and then continues to sample from all sectors to monitor fire growth. The vesda laserscanner is an air sampling smoke detector that offers area addressability. The vesda laserscanner is an aspirating smoke detector providing very early warning of fire conditions by drawing air samples through an air sampling pipe network. The laserplus incorporates a laser device and is classified as a class 1 laser product that complies with fda regulations 21 cfr 1040. Russian railways, the worlds third largest rail network.
Installation sheet for vesda laserplus and vesdalaserscanner. This filter removes dust contamination from sampled air and provides a clean air bleed to preserve the detector chamber optics. Vesdae the next generation of vesda aspirating smoke detectors. Vls detector with two blank plates and a scanner display module. Vesda early warning detectors are available in a variety of models to accommodate a broad range of environments and applications. The system shall consist of highly sensitive laser based smoke detectors with aspirators connected to networks of sampling pipes. Vesda laser scanner vls vesda laser plus vlp vesda laser compact vlc dst 1451 adm 14 user 1111. The laser emits invisible light and can be hazardous if viewed with the naked eye. Using unique detection principles, the vlp has an alarm sensitivity range of 0. If the smoke level reaches the adaptive scan threshold, the laser scanner quickly scans each pipe to. This vesda product incorporates a laser device and is classified as a class 1 laser. We have 1 xtralis vesda laserfocus vlf500 manual available for free pdf download.
The detector shall be laser based type and shall have an obscuration sensitivity range of 0. Contact us we are willing to respond to your inquiry. Return policy we carefully inspect the item before shipment. The laser scanner draws air from all sectors in use. A very early smoke detection system similar to the vesda laserscanner system shall be. The vlp is classed as a very early warning smoke detector, which means that it detects fire at the earliest. Vesda product manuals for the vesda laserplus, laserscanner, lasercompact. The vesda vlf250 model protects areas up to 250 square meters 2,500 square feet, and the vesda vlf500 model covers up to 500 square meters 5,000 square feet. Scenevision3d software is the industrys most advanced 3d laser scanner crime scene reconstruction software, used by more than 100 law enforcement agencies across the u. Vesda vls304 laserscanner asd 12 relays display panel. A 3d scanner is a device that analyzes a realworld object or environment to collect data on its shape and possibly its appearance i. Vesda, laser, vlp, vhh, relay, display, detect created date.
The vlp is classed as a very early warning smoke detector. Vesda laser plus ve70d vesda laser scanner vscan mini vesda50 vmin50 note. This is a open source 3d laser scanner targeted for cnc machinery but not only. Square off and deburr the end of the sampling air pipes, ensuring the pipes are free from swarf. Vesda laser focus vlf detector the vesda laser focus detector is a very early warning smoke detector designed to protect small, businesscritical environments of less than 500 m2 5000 sq. Indeed, rzhd already employs various vesda models from the vft15 addressable aspirating smoke detector, to laser compact vlc, laser focus vlf, laser plus vlp, and laser scanner vls to protect seven larger dccs on key rail lines, including privolzhsk, gorky, south ural, west siberian, oktyabrskaya railways, far eastern railways. The right side of the window includes a number pad.
The vesda vlpvlc detectors paved the way for aspirating smoke detection to evolve from a niche technology to a mainstay of the fire prevention industry. The vesda laserscanner detector will continue to sample from all sectors to monitor the fire growth and maintain full protection. Vesda laser scanner manual printable 2019 online reading at baseballaccessories. Pdf safety management on fire emergency response by. Laserplus, laserscanner, lasercompact, laserfocus, vesdanet. Legendary nikon optics in each nikon upright microscope provide superb images. Vesda ecoicam eco aspirating smoke detection combined with gas monitoring. Info free download books vesda laser scanner manual printable 2019 you know that reading vesda laser scanner manual printable 2019 is beneficial, because we could get enough detailed information online in the reading materials. Components of hvdc high voltage direct current capacitor. Configuring, wiring, and installing a vesda rs232 interface card in a 4100 4100u. Info free download books vesda laser scanner manual printable 2019 everyone knows that reading vesda laser scanner manual printable 2019 is helpful, because. The laserscanner is similar to the standard laserplus detector, but also includes a valve mechanism in the inlet manifold and software to control the airflow from the four vesda sectors pipes.
Safety management on fire emergency response by vesda applications at semiconductor plants. The laser scanner is similar to the standard laser plus detector, but also includes a valve mechanism in the inlet manifold and software to control the airflow from the four vesda sectors pipes. In case you found a defect on the purchase, we will exchange or refund it. When smoke is detected at a higher level than the scan threshold, for a period exceeding the configured scan delay 0 to 10 seconds, the detector performs a fast scan. Xtralis vlp the xtralis vesda vlp detector is the central element of the xtralis vesda asd product range. Vesda laser plus vlp detector the laser plus detector can be used for wide area.
The laser is housed in a sealed detector chamber and co ntains no serviceable parts. Each laserplus siemens modelseries device detects fire at the earliest possible stage, and reliably measures exceedingly low high concentrations of smoke. Registration on our support area is free and instant. Vls will be available in europe only until early 2020. Info free download books vesda laser scanner manual printable 2019 we all know that reading vesda laser scanner manual printable 2019 is helpful, because we are able to get a lot of information through the reading materials. Vesda laser scanner manual printable 2019 free reading at rhodeislandonline. It is the fastest way to settle your concern or issue.
A very early smoke detection system similar to the vesda laserscanner system. Please view our model comparison chart to determine which vesda model is. This configuration enables a single vesda zone to be divided into four separate sectors, for example, distinguishing between separate voids within a. The laser is housed in a sealed detector chamber and contains no. Disconnect the flow sensor cable connector 10 and scanner motor. Vesda smoke detector vpcoup fs coupling socket 34 xtralis box of 15. Vesda laserplus aspirating smoke detector vlp xtralis. Operation each laserscanner device draws air from all sectors in use. The system shall consist of highly sensitive laserbased smoke detectors with aspirators connected to networks of sampling pipes. The laser emits invisible light an d can be hazardous if viewed with the naked eye. This vesda product incorporates a laser device and is classified as a class 1 laser product that complies with fda regulations 21 cfr 1040. From small to very large, open spaces and from the cleanest to the dirtiest environments, vesda multilevel detection provides reliable, highsensitivity, very early warning smoke detection. The vesda laserscanner can monitor and individually report on four sectors in the protected area. It is assumed that persons troubleshooting a vesda laser system are knowledgeable about the local fire and electrical codes and standards.